HP of the Blower / Fan = ( CFM X PSI ) / ( 229 X Efficiency  of the blower )

Stands for CFM : Cubic Feet per Minute

PSI : Pounds per Square Inch

for Example .. after you determine air quantity of the Aeration Basin,

here we take roughly Require Air quantity =  650 M³/Hr ; Aeration Tank Depth is 4 Metre

Now Apply that figure into above formula,

Firstly, we convert M3/Hr to CFM

1 Metre³ = 35.31 Feet³

So, 650 Metre³ air require per Hour, hence 650 /60 = 10.833 M³ require per Minute

10.83 x 35.31 = 382.41 CFM air require / Minute

Secondly, we determine PSI using Depth 1 Metre Depth Water Column builds 1.42 psi

hence 4 metre Depth created 5.68 psi =  0.4 kg /cm²

Add 1 More metre, for Liquid Depth 4 metre vertical and One or half metre free drop of pipe and distribution pipes, valve’s throttle back pressure which you have fitted in the distribution line

hence we might add 1 to 2 metre roughly that will be better.

4 + 2 = 6 metre = 8.53 psi = 0.6 Kg/cm² is OK

similarly add 10 % Air volume = 383 + 38.3 =421.3 say 425 CFM

So, apply  this figure

HP =( 425 X 8.53 ) /( 229 X 0.69) = 10.9 HP say 11 HP Power, Air Blower Capacity is OK

60 TO 78 % Efficiency have Twin Lobe Air Blower,  here we took 69% efficiency

Check Blower Efficiency from Name Plate OR straight away ask to supplier.

Now, we should find Motor Capacity in HP

Simply ,

Motor HP = Blower Capacity in HP / Motor Efficiency

Normally it range 75 to 92 %, Here we take 85%

So,   = 11/0.85 = 13 HP

we make take 15 HP in motor Side else in neck to neck 12.5 HP.

Good Luck!! … drop your comments.

11 throughts on "Air Blower Capacity Selection for Aeration Tank"

  1. HP =( 425 X 8.53 ) /( 229 X 0.69) = 10.9 HP say 11 HP Power Please recheck calculation.

  2. hello. how can I determine the quantity of air 9″ fine bubble diffusers if blower flow rate and tank dimensions are given?

  3. Il we are a society of 50 flats and we habe 4 m3 aeration tank and we want buy blower for the same
    We have storage capacity of raw water 2 No’s and from this we take drainage water for treatment in aeration tank
    Please suggest best blower

Leave a Reply

Your email address will not be published. Required fields are marked *